Browse technical resources about solar mounting systems, tracker technology, structural design, and installation best practices.
HOME / 15 Battery Maintenance Checklist Every Car Owner - BeTheFuture Solar Foundation & Infrastructure
Lead acid and lithium-ion batteries dominate the market. This article offers a detailed comparison, covering chemistry, construction, pros, cons, applications, and operation.
Lead-acid batteries are the oldest technology and have the shortest lifespan, making them less popular for electric cars. Ultimately, each type of battery has its own pros and cons, and it's important to consider factors like cost, lifespan, and energy efficiency when comparing electric car batteries.
Lithium-ion batteries are lighter and more compact than lead-acid batteries for the same energy storage capacity. For example, a lead-acid battery might weigh 20-30 kilograms (kg) per kWh, while a lithium-ion battery could weigh only 5-10 kg per kWh.
The primary difference lies in their chemistry and energy density. Lithium-ion batteries are more efficient, lightweight, and have a longer lifespan than lead acid batteries. Why are lithium-ion batteries better for electric vehicles?
On contrary, lead is a carcinogenic material that is harmful to the environment. Even lead-acid batteries contain other chemicals such as sulphuric acid that are poisonous. But the recycling rate for lead-acid batteries is higher than Li batteries. Also, lead-acid batteries are cheaper because of their wide availability.
Lead-acid batteries remain an essential component in the battery industry. Despite not matching the energy capacity of newer batteries, their reliability, low cost, and high current delivery make Lead-acid batteries invaluable for certain uses.
2. Lead-Acid Batteries: Working: Lead-acid batteries utilize lead dioxide as the cathode and sponge lead as the anode immersed in a sulfuric acid electrolyte. During discharge, lead and lead dioxide react with sulfuric acid to produce electricity.
Proper Maintenance Tactics for Solar BatteriesCleaning Your Battery Regularly Cleaning your solar battery prevents dust and dirt from reducing its performance. Regular Prevention of Corrosion. Coating Metal Components with Commercial Sealant or High-temperature Grease.
Solar battery maintenance generally includes ensuring the battery is operating in the right temperature range, checking connections for signs of corrosion or looseness, and monitoring the battery's charge level to prevent it from getting too high or too low.
Apart from the flooded lead-acid battery, all the other battery technologies are advertised as being “maintenance-free”, because you don't have to do anything for them to work after installation. If you don't perform solar battery maintenance on a flood-lead acid battery from time to time, it'll be damaged and stop working.
Here are some tactics that can go a long way in ensuring optimal performance and longevity. Cleaning your solar battery prevents dust and dirt from reducing its performance. A mixture of baking soda and distilled water can be used to clean the battery case and terminals.
It is particularly useful if your battery system is exposed to temperature fluctuations, making it a helpful tool for optimal solar battery maintenance. A low-voltage disconnect will automatically disconnect the battery from the load when the voltage drops below a set level.
Cleaning your solar battery prevents dust and dirt from reducing its performance. A mixture of baking soda and distilled water can be used to clean the battery case and terminals. Corrosion on the terminals is a common problem that can lead to performance loss.
The bulk phase is where the battery gets recharged from 0-80% capacity. During the absorption stage, it is trickled charged for the remaining 20%. Finally, once the battery is fully charged, it enters the float phase. A good understanding of these phases is crucial in solar panel battery maintenance.
Luckily, sulfation can be reversed and prevented. The lead sulfate that has hardened and crystallized, which can't be removed by charging, can be removed by another process, called desulfation. This is the most important aspect of battery reconditioning. Applying a very high voltage to the battery plates. As we mentioned earlier, discharging a battery means sulfation will develop. Fact. There's nothing you can do about it. The more discharge, the more. Sulfation is not the only issue that can afflict batteries. There is also acid stratification, which can also be called acid layering. A well-rounded and full battery reconditioning process will also take action to fix this problem. If you. Around 50% of all breakdowns are due to battery failure. And as we said earlier, 84% of all battery failures are due to sulfation. That means the.
Lead acid batteries can sometimes sustain damage that cannot be repaired through reconditioning. A common issue is sulfation, where lead sulfate crystals accumulate on the battery plates. Severe sulfation may reduce the battery's capacity beyond recovery, making replacement necessary.
When charging a lead acid battery, sulfuric acid reacts with lead in the positive plates to produce lead sulfate and hydrogen ions. Simultaneously, lead in the negative plates reacts with hydrogen ions to form lead sulfate and release electrons. This chemical reaction generates electrical energy used to power devices.
Steps to Recondition a Lead-Acid Battery Safety First: Wear safety goggles and gloves to protect yourself from the corrosive acid. Remove the Battery: Take the battery out of the vehicle or equipment. Open the Cells: Remove the caps from the battery cells. Some batteries have screw-in caps, while others have rubber plugs.
Care must be taken when handling the new and the old battery acid as acid is highly corrosive and will cause acid burns and other damages. Prolonged exposure to battery acid is thought to cause cancer. You must use the right protective gear while handling acid. How Do You Put New Acid In Old Battery?
To add the new acid, follow the following steps; Step 1: Open the battery caps or rubber protections to access the battery cells. This is easily removed by hands without the need for any specialized tools. Step 2: Drain the battery of the old acid.
A lead-acid battery acts as a store of power because of the reaction between the lead plates and the electrolyte. The reason that both sulfation and acid stratification cause batteries to lose power and the ability to accept charge is because they both reduce the contact between the lead plates and the active electrolyte.
This article will provide an in-depth look at the best practices for extinguishing a lithium battery fire, including the types of extinguishers to use, safety precautions, and post-fire procedures.
The following fire extinguishers are specifically designed for use on lithium-ion battery fires which are not the same as standard lithium batteries (use a Class D L2 Powder Extinguisher on standard lithium battery fires).
Our lithium battery fire extinguishers are specially designed to put out such fires. Lith-ex fire extinguishers use a non-toxic and revolutionary extinguishing agent called AVD or Aqueous Vermiculite Dispersion, which is deployed as a mist to create a film over surfaces.
Application: Aim the extinguisher at the base of the fire, and apply the powder evenly to cover the burning material. Lithium-ion battery fires can be effectively managed with standard dry chemical or ABC fire extinguishers. These extinguishers use a dry chemical agent to interrupt the chemical reaction of the fire. Key Points:
Proper use of a lithium-ion fire extinguisher, following the manufacturer's instructions and ensuring it is rated specifically for lithium-ion battery fires, is essential for effectively managing these dangerous fires. Why Should You Also Have a Lithium-Ion Fire Blanket?
While CO2 extinguishers are effective for many types of fires, they are not suitable for lithium battery fires. They do not cool the battery sufficiently, and the fire may re-ignite once the CO2 dissipates. If it is safe to do so, disconnect the battery or power source to cut off the supply of electricity.
Foam extinguishers are also ineffective and unsafe for lithium battery fires. While CO2 extinguishers are effective for many types of fires, they are not suitable for lithium battery fires. They do not cool the battery sufficiently, and the fire may re-ignite once the CO2 dissipates.
The end result may include (a) physical expansion of plates, (b) increased internal resistance, (c) reduced power capability, and (d) eventual battery failure.
If the water level gets too low, the plates will start to corrode and the battery will eventually fail. If you have a lead-acid battery, it is important to keep it full of water. If the water level gets too low, the battery are ruined. What Happens If Lead Acid Battery Runs Out of Water?
When a lead acid battery is drained of its acid, the wet moist negative electrodes come in contact with atmospheric oxygen, triggering an exothermic reaction that releases heat and discharges the negative plates (electrodes), oxidizing the sponge lead to lead oxide.
A lead acid battery is a type of rechargeable battery that has positive and negative plates fully immersed in electrolyte, which is dilute sulphuric acid.
A lead acid battery, including flooded electrolyte types, should not have its acid completely removed once it has been filled and charged. It is important not to remove the acid. A lead acid battery consists of several major components, including the positive electrode, negative electrode, sulphuric acid, separators, and tubular bags.
If you have a lead acid battery to charge it, it's important to keep it filled with water. If the battery runs out of water, it will no longer be able to generate power. The lead plates in the battery will start to corrode, and the battery will eventually fail. Will Tap Water Ruin a Battery?
Flooded electrolyte lead acid batteries do not cause thermal runaway because the electrolyte, which acts as a coolant in these batteries, helps prevent such an occurrence. Designers of flooded electrolyte lead acid batteries do not face the thermal runaway problems that are common in sealed maintenance free (SMF) or valve regulated lead acid (VRLA) batteries.
These advanced materials include mica, intumescent materials, and ablative coatings. Each material offers unique properties and benefits suitable for different aspects of battery protection.
Foams also act as thermal and electrical conductors, depending on their material and the compression amount within the battery. An extra layer can be added to the foam to make it more suitable for EMI shielding. Battery components need protection from electromagnetic waves due to their high frequencies and small size.
Regarding EV battery production, foam ensures optimal performance and longevity. Foam is widely used as an insulation material within battery packs, protecting the cells from extreme temperatures and vibrations. This insulation not only enhances safety but also helps maximise energy efficiency.
One plug-in hybrid EV built in China is already using a thermoplastic polypropylene compound instead of aluminium for its battery case cover, providing savings in weight. Other EVs now in production around world are using several thermoplastic materials for components such as cell carriers and housings, battery modules and battery enclosures.
Polyurethane foam, silicone foam, and Ethylene-Vinyl Acetate (EVA) foam are commonly used foams in EV battery manufacturing. Each type serves specific purposes, such as thermal, electrical, and shock absorption. What are some advancements in foam technology for EV batteries?
Additionally, polyurethane foam provides structural support, reducing the risk of damage due to shocks or vibrations. Silicone foam, another popular choice, excels in maintaining electrical insulation. Creating a barrier against moisture and dust ingress ensures the battery pack's long-term reliability.
These foams are built with fire-resistant materials, ensuring if something such as thermal runaway occurs in the battery, the foam will be an essential factor in reducing the chances of spreading. Dielectric foams and insulation are critical components to protecting the battery cells as they expand and contract while in use.
The liquid-filled lead acid batteries used in automobiles and a range of other products have many great qualities, but are also known to “go bad” with little warning. Fortunately, you can easily do a basic health checkup on any.
Lead acid batteries recharge in various manners based on their function and manner of installation. For a lead acid vehicle battery, drive the vehicle around for at least 20 minutes. For a lead acid battery connected to solar panels, let the battery charge fully on a sunny day.
Fortunately, you can easily do a basic health checkup on any type of lead acid battery by hooking it up to a simple-to-use digital voltmeter. If you have an open-cell battery that lets you access the liquid inside, you can do a more rigorous checkup with a battery hydrometer. Charge the battery fully, then let it rest for 4 hours.
The liquid-filled lead acid batteries used in automobiles and a range of other products have many great qualities, but are also known to “go bad” with little warning. Fortunately, you can easily do a basic health checkup on any type of lead acid battery by hooking it up to a simple-to-use digital voltmeter.
Lead-acid batteries are a type of rechargeable battery that uses lead and lead oxide electrodes submerged in an electrolyte solution of sulfuric acid and water. They are commonly used in vehicles, backup power supplies, and other applications that require a reliable and long-lasting source of energy.
To get a more accurate reading of a lead-acid battery's health, you can use a hydrometer. This tool measures the specific gravity of the electrolyte solution within the battery, which can give you a better idea of its state of charge and overall condition. Before using a hydrometer, it's important to make sure the battery is fully charged.
Checking an open-cell lead acid battery—that is, a lead acid battery with caps that can be opened to access the liquid inside—with a battery hydrometer is most accurate when the battery is fully charged. Closed-cell lead acid batteries without the access caps cannot be tested this way.
The average Lithium RV battery costs between $350 to $700. Though the prices tend to come down over time as lithium material refining, technology and availability are improving rapidly.
By contrast, the average cost of an RV lithium battery in today's market can easily exceed $1300. If you are looking at initial cost alone, lead-acid batteries are still the way to go. But consider this: The average life span of a lead-acid battery is about five years while lithium RV batteries can last up to 10 times longer.
The reality of lithium RV batteries is that they are a worthwhile investment if you like to dry camp, boondocking, and and planning for long-term RV living & traveling. Consider that the average lead-acid battery is rated for about 400 charge-discharge cycles, and that's the high end.
You'll find lithium-ion batteries in most phones and laptops today. The lithium batteries that are highly popular for use in RVs are lithium iron phosphate batteries. These are top choices due to their long lifespan, low toxicity, high safety, and relatively lower cost. Lithium batteries are a game changer in terms of performance.
Yes, you can replace your RV battery with a lithium battery. You can easily upgrade to this popular option as long as the batteries have the same voltage. However, the one caveat comes down to the RV's charger. If your charger doesn't specifically support lithium batteries, it will still work but less efficiently.
But consider this: The average life span of a lead-acid battery is about five years while lithium RV batteries can last up to 10 times longer. That prompts us to do a little math. Let's say you stick to the lead-acid battery route and replace your battery every five years, on average.
RV lithium batteries offer up to 15% higher charging efficiency (on average). They can also be charged at a much higher amperage, which means they reach a full charge much faster than a lead-acid battery. Many of them also weigh half as much as a lead-acid battery with an equivalent energy rating.
The basic concept is that when connecting in parallel, you add the amp hour ratings of the batteries together, but the voltage remains the same. For example: 1. two 6 volt 4.5 Ah batteries wired in parallel are capable of providing 6 volt 9 amp hours (4.5 Ah + 4.5 Ah). 2. four 1.2 volt 2,000 mAh wired in parallel can provide 1.2. This is the big “no go area”. The battery with the higher voltage will attempt to charge the battery with the lower voltage to create a balance in the circuit. 1. primary (disposable). This is possible and won't cause any major issues, but it is important to note some potential issues: 1. Check your battery chemistries – Sealed Lead Acid batteries for example.
To properly wire a battery pack in series follow the illustration below. Some electric scooter, bike, and go kart batteries are wired in series and parallel to create a battery pack with a Voltage that is half the sum of all of the batteries in the pack combined.
A battery parallel assembly comprises multiple battery cells connected electrically in parallel under a specific topological configuration or geometrical arrangement. In this example, you create a parallel assembly of four cylindrical cells stacked in a square topology over four rows.
Flow batteries and other chemistries. These are commonly available in 48V. Multiple batteries can connect in parallel without any issues. Each battery has its own battery management system. Together they will generate a total state of charge value for the whole battery bank. A GX monitoring device is needed in the system.
When batteries are connected in series, the voltage increases. When batteries are connected in parallel, the capacity increases. When batteries are connected in series/parallel, both the voltage and the capacity increase. Single battery. Two batteries in series. Two batteries in parallel. Four batteries in series/parallel. Four batteries in series.
The basic concept is that when connecting in parallel, you add the amp hour ratings of the batteries together, but the voltage remains the same. For example: two 6 volt 4.5 Ah batteries wired in parallel are capable of providing 6 volt 9 amp hours (4.5 Ah + 4.5 Ah).
To wire multiple batteries in parallel, connect the negative terminal (-) of one battery to the negative terminal (-) of another, and do the same to the positive terminals (+). For example, you can connect four Renogy 12V 200Ah Core Series LiFePO4 Batteries in parallel. In this system, the system voltage and current are calculated as follows:
A dual-purpose lithium iron phosphate battery that combines the power of a starter battery with the cycle life of a deep-cycle battery. It's better than lead-acid in almost every way.
Lithium-sulfur batteries are next-generation energy storage systems that promise substantial benefits over traditional lithium-ion batteries, including higher energy density, lower production costs, and reduced environmental impact. Their properties make them a good candidate for applications such as EVs, aerospace, and grid energy storage.
Future Potential: Could replace traditional lithium-ion in EVs with extended range As the name suggests, Lithium-metal batteries use lithium metal as the anode. This allows for substantially higher energy density—almost double that of traditional lithium-ion batteries.
Plus, some prototypes demonstrate energy densities up to 500 Wh/kg, a notable improvement over the 250-300 Wh/kg range typical for lithium-ion batteries. Looking ahead, the lithium metal battery market is projected to surpass $68.7 billion by 2032, growing at an impressive CAGR of 21.96%. 9. Aluminum-Air Batteries
As the name suggests, Lithium-metal batteries use lithium metal as the anode. This allows for substantially higher energy density—almost double that of traditional lithium-ion batteries. They are lighter, capable of delivering more power, and have potential for extended lifecycles when properly designed. How Do They Work?
Future Potential: Inexpensive and highly scalable for renewable energy storage Zinc-air batteries are emerging as a promising alternative in the energy storage field due to their high energy density, cost-effectiveness, and environmental benefits. They have an energy density of up to 400 Wh/kg, rivaling lithium-ion batteries.
Lithium-ion (Li-ion) batteries are considered the prime candidate for both EVs and energy storage technologies, but the limitations in term of cost, performance and the constrained lithium supply have also attracted wide attention, .
You have a couple of recharging solutions to consider should your electric car run out of battery: If it is not possible to recharge at a nearby charging station then you can use a portable charger or call for a breakdown cover provider who will charge the EV with a partial charge or tow you to a charging station. Here's a. So, power is starting to run out or you've come to a complete stop, let's look at your options: 1. Find a nearby charging station Yep – captain obvious. The most common-sense answer is. Most EVs provide real-time information about the battery's state of charge, so it's really easy for drivers to see how low the battery is getting. Here are. Try to keep calm, this is stressful but panicking can make the situation worse. As soon as you notice your battery is running critically low or the car starts to lose power you should pull over safely onto the hard shoulder or. An electric car could potentially travel for around 10-40 miles on a low battery before running out of power (estimated for a battery of around 10%.
[PDF Version]You have a couple of recharging solutions to consider should your electric car run out of battery: If it is not possible to recharge at a nearby charging station then you can use a portable charger or call for a breakdown cover provider who will charge the EV with a partial charge or tow you to a charging station.
The best way to avoid running out of battery is to ensure you're never in that position; this is much easier nowadays with improved EVs. Be careful not to charge your EV to 100% too often or drain it to 0%, as doing either can damage your battery condition, limiting your battery life and range.
As soon as you notice your battery is running critically low or the car starts to lose power you should pull over safely onto the hard shoulder or the nearest safe area away from the traffic. Turn on your hazard lights to alert other drivers and place a warning triangle at a safe distance behind the car.
On the off chance you do run out of electricity, contact your breakdown provider. It may have a small battery booster that can give you enough charge to get to a charging station. If not, ask for a flatbed truck to take you to a nearby charging station.
When an electric car runs out of battery the power to the electric motor will eventually stop. The electric motor is pretty important, as you can imagine, it makes the vehicle drive! So the car will gradually lose speed and eventually come to a complete stop.
If you run out of battery power, there is less of a chance you'll damage your EV's powertrain than if you were to starve an internal combustion engine of fuel. For instance, EVs don't have a fuel pump or fuel filter that can be damaged by running the engine with an empty fuel tank. An EV will simply slow down and, eventually, completely shut down.
For winter storage, disconnect the batteries, charge them to 50%, and store them in a dry, well-ventilated place. Don't let them get below -15°F (-26°C).
By following the right storage practices, you'll be ensuring your battery lasts longer, and your devices keep running smoothly for years to come. The first rule of battery storage is simple—never store a lithium-ion battery in an environment that's too hot or too cold. These batteries work best in moderate, room-temperature environments.
Regular maintenance and safety checks are important to ensure a safe environment for storing and handling lithium-ion batteries. This isn't a one-off task but an ongoing commitment, so scheduling regular inspections of your storage solutions is key. It's also important to keep an eye on the batteries themselves.
Follow guidelines for cleaning, disconnecting, and choosing the right storage location to safeguard your batteries. Monitoring and maintenance during winter storage are crucial for preserving lithium batteries. Regular inspection, temperature monitoring, and maintenance charging help ensure optimal battery health and performance.
The UK doesn't have specific regulations or legislation for the general storage of lithium-ion batteries. The Health and Safety Executive has, however, published guidance on good practices for handling and storing batteries, even though it is not compulsory. Regulations are not prescriptive but instead follow the typical routes:
Lithium-ion battery fires can even reignite after being contained. In this post, we'll talk through the safe storage requirements for lithium-ion batteries that manage the risks to keep people and facilities safe. The UK doesn't have specific regulations or legislation for the general storage of lithium-ion batteries.
Handle with Care: When handling the batteries, be mindful of their fragility and avoid dropping or mishandling them. Lithium batteries are sensitive to physical impact, and any damage to the battery casing can compromise their integrity and safety. 7.
The increase in battery demand drives the demand for critical materials. In 2022, lithium demand exceeded supply (as in 2021) despite the 180% increase in production since 2017. In 2022, about 60% of lithium, 30% of cobalt and 10% of nickel demand was for EV batteries. Just five years earlier, in 2017, these shares were. In 2022, lithium nickel manganese cobalt oxide (NMC) remained the dominant battery chemistry with a market share of 60%, followed by lithium iron phosphate (LFP) with a share of just under 30%, and nickel cobalt aluminium. With regards to anodes, a number of chemistry changes have the potential to improve energy density (watt-hour per kilogram, or Wh/kg). For example, silicon can be used to replace all or some of the graphite in the anode in.
The global sodium-ion battery market size was estimated at USD 321.75 million in 2023 and is expected to grow at a CAGR of 16.3% from 2024 to 2030. The global market is experiencing significant growth and is poised for further expansion in the coming years.
The market for sodium-ion batteries was estimated to be worth roughly USD 1120 million in 2021, and it is anticipated to grow to USD 2899 million by 2030. The market is expected to grow significantly over the coming years as a result of a number of driving factors.
Sodium-ion batteries play a crucial role in the transition towards cleaner and more abundant energy storage technologies and drive the Sodium-Ion Battery Market. The sodium-ion battery market demand is driven by the growing integration of renewable energy sources.
The sodium ion battery market in the U.S. is expected to grow at a CAGR of 18.9% from 2024 to 2030. Increasing demand for sodium-ion batteries from sectors like electric utilities, transportation (potentially for low-range EVs or commercial fleets), and industrial applications requiring reliable and cost-effective energy storage.
The sample report only takes 30 secs to download, no need to wait longer. The global sodium-ion battery market size was valued at USD 1025 million in 2021 and is estimated to reach an expected value of USD 2665 million by 2030, growing at a CAGR of 11.2% during the forecast period (2022 - 2030).
The Sodium-ion Battery market is divided into types and end-users for the purposes of our study. The sodium-Sulfur batteries category is predicted to rule the sodium-ion battery market in 2021 based on type. In sodium-sulfur (NAS) batteries, a type of sodium-ion battery, there is a lithium sulphide cathode and a sodium anode.
Lithium batteries' huge energy capacity means they last longer for each charge and are capable of easily 10 times more cycles (number of times they can be charged and discharged) than lead-acid batteries. Our lives are now so jammed full of technology of all kinds, and modern equipment and appliances are so power. The Ah number shows how much energy can be delivered by the battery over a period of time. So a 100Ah battery coulddeliver 100 Amps for. Depth of Discharge refers to the % you can discharge your battery. When you reach that % you must you must recharge. For lead-acid batteries, you can discharge your battery to 50%. Use. Lithium batteries extremely long lifespan and capability for a huge number of cycles means that it works out much cheaper than lead-acid batteries. Battery lifespan can be measure in cycles – that is discharge/charge cycles a battery is capable before it's ability to deliver power diminishes and it.
[PDF Version]
When the electrolyte in a lithium-ion battery freezes, it can cause the formation of lithium metal on the surface of the electrodes inside the battery. This can create a physical barrier that prevents the flow of ions between the. To maximize the efficiency of a lithium-ion battery at low temperatures, there are several strategies that can be used: 1.Keep the battery warm: One of the most effective ways to maintain. The runtime of a lithium-ion battery depends on several factors, including the capacity of the battery, the power requirements of the device.
Low-temperature batteries are designed to maintain performance in cold environments. In contrast, standard batteries often experience reduced capacity and efficiency in low temperatures.
Battery certification plays a crucial role in ensuring the safety and performance of battery products across various industries. In this guide, we'll break down the essential certifications you need to know, including the types of certifications, the costs involved, expected timeframes, and the standards that govern them.
Low-temperature batteries may sacrifice some capacity or energy density to maintain performance in cold environments. In contrast, standard batteries typically offer higher capacity and energy density under normal operating conditions. Standard batteries may perform better in moderate temperatures but struggle in colder climates.
The lowest temperature at which most batteries can operate without damage is typically around -20 °C to -40 °C (- 4°F to 40°F). However, this can vary depending on the type of battery and its chemistry. What is the low temperature for a LiPo battery? LiPo batteries perform best at temperatures above 0°C (32°F).
LiFePO4 batteries can generally operate safely down to around -20°C. Beyond this temperature, their performance may decline, potentially damaging them. The low temperature li-ion battery solves energy storage in extreme conditions. This article covers its definition, benefits, limitations, and key uses.
In Europe, lithium-ion batteries must meet CE Marking requirements for safety, health, and environmental standards. Additional certifications like IEC 62133 or UN38.3 may be needed for transport and use. What to consider when choosing a certification body?