Browse technical resources about solar mounting systems, tracker technology, structural design, and installation best practices.
HOME / A Mathematical Model For The Soluble Lead Acid Flow Battery - BeTheFuture Solar Foundation & Infrastructure
The electrochemistry of static lead-acid and soluble lead-acid flow batteries is summarised and the differences between the two batteries are highlighted. A general comparison of the performance of an un.
A scaled-up soluble lead-acid flow battery has been demonstrated, operating both as a single cell and as a bipolar, two-cell stack. Using short charge times (900 s at ≤20 mA cm −2) the battery successfully runs for numerous charge/discharge cycles.
Following a large number of charge/discharge cycles, a soluble lead-acid flow battery could fail due to cell shorting caused by the growth of lead and lead dioxide deposition the negative and positive electrode, respectively.
As a flow battery, the soluble lead acid battery is also unique in that no microporous separator (typically a cation-exchange membrane such as Nafion) is required and a single reservoir is used for the electrolyte, allowing for a simpler design and a substantial reduction in cost.
Conclusions 1. The electrochemistries of the soluble lead-acid flow battery and the static lead-acid battery are distinctly different; in the soluble lead acid battery lead is highly soluble in the electrolyte of methanesulfonic acid, while lead is a solid paste in the static lead-acid battery.
Self-discharge was also observed in the case of the soluble lead-acid flow battery when it was left open-circuit for a long time period. To test the self-discharge characteristic of a soluble lead-acid flow battery, a series of charge/discharge cycles were performed.
Traditional lead-acid batteries (e.g., SLI, starting lighting ignition) batteries for automotive applications) operate with an electrolyte, typically sulphuric acid, in which lead compounds are only sparingly soluble. Consequently, an insoluble paste containing the active materials is normally applied to each of the electrodes.
A lead acid battery can supply up to 1400 amps, depending on its size and usage. Cold Cranking Amps (CCA) measures performance at 32°F (0°C), while Marine Cranking Amps (MCA) measures at 40°F.
The number of amps you should use to charge a 12V lead acid battery depends on its capacity. As a general rule, you should use a charging current of 10% of the battery's capacity. For example, a 100Ah battery should be charged with a current of 10A.
As a general rule, you should use a charging current of 10% of the battery's capacity. For example, a 100Ah battery should be charged with a current of 10A. In conclusion, the recommended charging current for a new lead acid battery depends on the battery capacity and the charging method used.
Unlike LiPo batteries with have a maximum current rating, the lead acid battery only stated the "initial current", which is used for charging. The label stated not to short the battery. Hence, may I know what/how to find out the safe current to draw? How will the battery fail if I draw too much current (explode/lifespan decreased/?)? Thanks
Customers often ask us about the ideal charging current for recharging our AGM sealed lead acid batteries. We have the answer: 25% of the battery capacity. The battery capacity is indicated by Ah (Ampere Hour). For example: In a 12V 45Ah Sealed Lead Acid Battery, the capacity is 45 Ah.
Lead acid batteries are one of the most common types of rechargeable batteries used in various applications, including cars, boats, and backup power systems. These batteries are known for their durability, low cost, and high energy density. A lead acid battery consists of lead plates submerged in an electrolyte solution of sulfuric acid and water.
This comes to 167 watt-hours per kilogram of reactants, but in practice, a lead–acid cell gives only 30–40 watt-hours per kilogram of battery, due to the mass of the water and other constituent parts. In the fully-charged state, the negative plate consists of lead, and the positive plate is lead dioxide.
To maintain lead acid car batteries, use distilled or de-ionized water. Regularly add this water to the electrolyte to replace lost moisture from evaporation. This action keeps the water level stable.
Gassing causes water loss, so lead acid batteries need water added periodically. Low-maintenance batteries like AGM batteries are the exception because they have the ability to compensate for water loss. Overwatering and underwatering can both damage your battery. Follow these watering guidelines to keep your lead battery running at peak levels.
One of the most important factors to consider when it comes to lead acid battery maintenance is the water level. Keeping the battery hydrated means that you will have to water your battery regularly. Putting too much water in the cells reduces capacity and conversely not watering them often enough does internal damage both of which are undesirable.
The AFS makes lead acid battery watering safe, easy and affordable; designed from the ground up with those key targets in mind. It fills an industrial forklift lead-acid battery in one-tenth the time of hand watering, which means that these systems typically pay for themselves in under a year.
Lead acid batteries consist of flat lead plates immersed in a pool of electrolytes. The electrolyte consists of water and sulfuric acid. The size of the battery plates and the amount of electrolyte determines the amount of charge lead acid batteries can store or how many hours of use. Water is a vital part of how a lead battery functions.
The two most common lead acid batteries are flooded, which require regular watering intervals and VRLA which deliver nearly maintenance-free operation. Make sure you check the information on the battery if you're unsure which battery you have.
Lead-acid batteries generate electricity through an electrochemical reaction between lead plates and electrolytes. The electrolytes are a mixture of water and sulphuric acid. And the water protects the battery's active material while it generates power. Without water, the active material will oxidize and the battery will lose power.
Slower charging occurs when a lead acid battery takes longer to reach a full charge. Aging batteries exhibit increased internal resistance, which impedes the flow of current during charging.
Experiments on a 12 V 50 Ah Valve Regulated Lead Acid (VRLA) battery indicated the possibility of 100 % charge in about 6 h, however, with high gas evolution. As a result, the feasibility of multi-step constant current charging with rest time was established as a method for fast charging in lead-acid batteries.
The following mainly analyzes the lead-acid battery short circuit caused by excessive charging current, charging voltage of a single battery exceeds 2.4V, internal short-circuit or partial discharge, excessive temperature rise and valve control failure, and summarizes the treatment methods of lead acid battery short circuit as follows:
Lead acid is sluggish and cannot be charged as quickly as other battery systems. (See BU-202: New Lead Acid Systems) With the CCCV method, lead acid batteries are charged in three stages, which are constant-current charge, topping charge and float charge.
Even in storage, lead-acid batteries naturally lose charge over time, and failure to periodically recharge them can result in irreversible damage. 8. Proper Disposal and Recycling of Lead-Acid Batteries Lead-acid batteries contain hazardous materials, including lead and sulfuric acid, making proper disposal crucial.
Temperature Control: Ideally, lead-acid batteries should be charged at temperatures below 80°F (27°C). Charging at high temperatures can lead to thermal runaway, where the battery overheats and becomes damaged. If your battery becomes hot to the touch during charging, stop the process immediately and allow it to cool. 4. Avoiding Overcharging
The most important first step in charging a lead-acid battery is selecting the correct charger. Lead-acid batteries come in different types, including flooded (wet), absorbed glass mat (AGM), and gel batteries. Each type has specific charging requirements regarding voltage and current levels.
Lead-acid batteries are suitable for applications with large capacity and low cost, while lithium batteries are suitable for occasions requiring energy density, weight and volume.
Battery storage is becoming an increasingly popular addition to solar energy systems. Two of the most common battery chemistry types are lithium-ion and lead acid. As their names imply, lithium-ion batteries are made with the metal lithium, while lead-acid batteries are made with lead. How do lithium-ion and lead acid batteries work?
Lead acid batteries, while generally safer in terms of risk of fire, can also pose risks, particularly due to their corrosive acid. However, they are generally less sensitive to environmental conditions and physical impacts compared to lithium batteries. Can lead-acid batteries and lithium batteries be charged with each other?
Electrolyte: A lithium salt solution in an organic solvent that facilitates the flow of lithium ions between the cathode and anode. Chemistry: Lead acid batteries operate on chemical reactions between lead dioxide (PbO2) as the positive plate, sponge lead (Pb) as the negative plate, and a sulfuric acid (H2SO4) electrolyte.
Lithium-ion batteries are lighter and more compact than lead-acid batteries for the same energy storage capacity. For example, a lead-acid battery might weigh 20-30 kilograms (kg) per kWh, while a lithium-ion battery could weigh only 5-10 kg per kWh.
Energy Density and Weight One of the most significant differences between lithium iron phosphate and lead acid batteries is energy density. Lithium ion batteries are much lighter and more compact, offering a higher energy density, which means they can store more energy in a smaller space.
When it comes to humidity exposure, lithium-ion batteries have better resilience than lead-acid. Lithium-ion batteries have a robust casing that is completely sealed, therefore, moisture does not get to the internal components of the battery.
The liquid-filled lead acid batteries used in automobiles and a range of other products have many great qualities, but are also known to “go bad” with little warning. Fortunately, you can easily do a basic health checkup on any.
Lead acid batteries recharge in various manners based on their function and manner of installation. For a lead acid vehicle battery, drive the vehicle around for at least 20 minutes. For a lead acid battery connected to solar panels, let the battery charge fully on a sunny day.
Fortunately, you can easily do a basic health checkup on any type of lead acid battery by hooking it up to a simple-to-use digital voltmeter. If you have an open-cell battery that lets you access the liquid inside, you can do a more rigorous checkup with a battery hydrometer. Charge the battery fully, then let it rest for 4 hours.
The liquid-filled lead acid batteries used in automobiles and a range of other products have many great qualities, but are also known to “go bad” with little warning. Fortunately, you can easily do a basic health checkup on any type of lead acid battery by hooking it up to a simple-to-use digital voltmeter.
Lead-acid batteries are a type of rechargeable battery that uses lead and lead oxide electrodes submerged in an electrolyte solution of sulfuric acid and water. They are commonly used in vehicles, backup power supplies, and other applications that require a reliable and long-lasting source of energy.
To get a more accurate reading of a lead-acid battery's health, you can use a hydrometer. This tool measures the specific gravity of the electrolyte solution within the battery, which can give you a better idea of its state of charge and overall condition. Before using a hydrometer, it's important to make sure the battery is fully charged.
Checking an open-cell lead acid battery—that is, a lead acid battery with caps that can be opened to access the liquid inside—with a battery hydrometer is most accurate when the battery is fully charged. Closed-cell lead acid batteries without the access caps cannot be tested this way.
In this forward-looking report, FutureBridge explores the rising momentum behind vanadium redox and alternative flow battery chemistries, outlining innovation paths, deployment challenges, and market projections.
In the pursuit of sustainable and reliable energy storage solutions, Vanadium Redox Flow Batteries offer a compelling combination of safety, longevity, and recyclability - key attributes of any truly environmentally friendly and long-duration energy storage technology.
In the 1980s, the University of New South Wales in Australia started to develop vanadium flow batteries (VFBs). Soon after, Zn-based RFBs were widely reported to be in use due to the high adaptability of Zn-metal anodes to aqueous systems, with Zn/Br2 systems being among the first to be reported.
In contrast, technologies like vanadium redox flow batteries (VRFBs) rely on reusable liquid electrolytes and recyclable hardware, enabling a more robust and predictable pathway toward circular energy storage.
Valuation of Long-Duration Storage: Flow batteries are ideally suited for longer duration (8+ hours) applications; however, existing wholesale electricity market rules assign minimal incremental value to longer durations.
Flow battery developers must balance meeting current market needs while trying to develop longer duration systems because most of their income will come from the shorter discharge durations. Currently, adding additional energy capacity just adds to the cost of the system.
That arrangement addresses the two major challenges with flow batteries. First, vanadium doesn't degrade. “If you put 100 grams of vanadium into your battery and you come back in 100 years, you should be able to recover 100 grams of that vanadium—as long as the battery doesn't have some sort of a physical leak,” says Brushett.
Nickel–cadmium technology has seen enormous technical improvement because of the advantages of high specific power (over 220 W/kg), long cycle life (up to 2000 cycles), high tolerance of electric and mechanical abuse, a small voltage drop over a wide range of discharge currents, rapid charge capability (about 40%–80% in 18 min), wide operating temperature range (−40°C to −85°C), low self-discharge rate (<0. 5% per day), excellent long-term storage due to negligible corrosion, and availability in a variety of size designs.
For poorly informed system designers, the knowledge of batteries is limited and they often easily decide on a standard choice such as lead–acid battery or a newly very popular lithium–ion battery. However, nickel–cadmium batteries are very attractive for many applications and their performance makes them superior for many conditions.
In this chapter, the principle of operation of nickel–cadmium batteries, their charge–discharge cycles, processes in the overcharge phase, self-discharge, memory effect, and failure modes are explained. Batteries using nickel negative electrodes are commonly called nickel-based batteries or simply nickel batteries.
Nickel–cadmium batteries were invented at the turn of the nineteenth to twentieth century and since that time have been a popular battery choice for many applications, in particular when high current or a high number of cycles is needed for an application. In...
Batteries using nickel negative electrodes are commonly called nickel-based batteries or simply nickel batteries. The first commercial battery system based on nickel electrode was nickel–cadmium, invented in 1899.
The most common failure modes in nickel–cadmium batteries are electrical shorts caused by the growth of cadmium dendrites and penetration through the separator, passivation, and wear of active materials, destruction of the separator, and swelling of positive active mass.
A useful procedure to maintain full capacity of nickel–cadmium batteries at all times is to use trickle charge simply to offset the self-discharge rate and keep the battery fully charged. If this is not possible, a battery should be stored in cool conditions.
The main difference between flow batteries and other rechargeable battery types is that the aqueous electrolyte solution usually found in other batteries is not stored in the cells around the positive electrode a.
Scalability: One of the standout features of flow batteries is their inherent scalability. The energy storage capacity of a flow battery can be easily increased by adding larger tanks to store more electrolyte.
Renewable Energy Storage: One of the most promising uses of flow batteries is in the storage of energy from renewable sources such as solar and wind. Since these energy sources are intermittent, flow batteries can store excess energy during times of peak generation and discharge it when demand is high, providing a stable energy supply.
Flow batteries typically include three major components: the cell stack (CS), electrolyte storage (ES) and auxiliary parts. A flow battery's cell stack (CS) consists of electrodes and a membrane. It is where electrochemical reactions occur between two electrolytes, converting chemical energy into electrical energy.
Flow batteries differ from other types of rechargeable solar batteries in that their energy-storing components—the electrolytes—are housed externally in tanks, not within the cells themselves. The size of these tanks dictates the battery's capacity to generate electricity: larger tanks mean more energy storage.
Flow batteries can be operated similarly to fuel cells, or they can be recharged with electricity, allowing the liquids to be used repeatedly. They have advantages like the ability to scale energy and power independently and a long lifespan.
You might believe that flow batteries are a new technology merely invented over the past few years. Actually, the development of flow batteries can be traced back to the 1970s when Lawrence Thaller at NASA created the first prototype of this battery type.
The zinc–bromine (ZBRFB) is a hybrid flow battery. A solution of is stored in two tanks. When the battery is charged or discharged, the solutions (electrolytes) are pumped through a reactor stack from one tank to the other. One tank is used to store the electrolyte for positive electrode reactions, and the other stores the negative. range between 60 and 85 W·h/kg.
Zinc bromine flow batteries or Zinc bromine redux flow batteries (ZBFBs or ZBFRBs) are a type of rechargeable electrochemical energy storage system that relies on the redox reactions between zinc and bromine. Like all flow batteries, ZFBs are unique in that the electrolytes are not solid-state that store energy in metals.
Three examples of zinc–bromine flow batteries are ZBB Energy Corporation′s Zinc Energy Storage System (ZESS), RedFlow Limited′s Zinc Bromine Module (ZBM), and Premium Power′s Zinc-Flow Technology.
Zinc-bromine flow batteries (ZBFBs) offer great potential for large-scale energy storage owing to the inherent high energy density and low cost. However, practical applications of this technology are hindered by low power density and short cycle life, mainly due to large polarization and non-uniform zinc deposition.
While zinc bromine flow batteries offer a plethora of benefits, they do come with certain challenges. These include lower energy density compared to lithium-ion batteries, lower round-trip efficiency, and the need for periodic full discharges to prevent the formation of zinc dendrites, which could puncture the separator.
The leading potential application is stationary energy storage, either for the grid, or for domestic or stand-alone power systems. The aqueous electrolyte makes the system less prone to overheating and fire compared with lithium-ion battery systems. Zinc–bromine batteries can be split into two groups: flow batteries and non-flow batteries.
In the early stage of zinc–bromine batteries, electrodes were immersed in a non-flowing solution of zinc–bromide that was developed as a flowing electrolyte over time. Both the zinc–bromine static (non-flow) system and the flow system share the same electrochemistry, albeit with different features and limitations.
Here, we report an aqueous biphasic system based on imidazolium ionic liquids (ILs) for constructing membrane-free self-stratified aqueous biphasic Zn–I and Zn–Br batteries.
Among the above-mentioned flow batteries, the zinc-based flow batteries that leverage the plating-stripping process of the zinc redox couples in the anode are very promising for distributed energy storage because of their attractive features of high safety, high energy density, and low cost .
Unlike that conventional flow batteries operate on the basis of liquid-liquid conversions, the Zn anode in Zn-FBs adopts a solid-liquid conversion reaction, presenting challenges such as dendrite formation, poor reversibility, and low areal capacity, limiting its long-duration energy storage (LDES) applications.
Among the above-mentioned zinc-based flow batteries, the zinc-bromine flow batteries are one of the few batteries in which the anolyte and catholyte are completely consistent. This avoids the cross-contamination of the electrolyte and makes the regeneration of electrolytes simple.
The electricity produced from renewables is volatile and intermittent, which is one of the big obstacles for their widespread applications. Energy storage technology, flow battery technologies in particular, is a safe and effective approach to address this issue .
Currently, the flow battery can be divided into traditional flow batteries such as vanadium flow batteries, zinc-based flow batteries, and iron-chromium flow batteries, and new flow battery systems such as organic-based flow batteries, which hold great promise for energy storage applications.
Since the 1970s, various types of zinc-based flow batteries based on different positive redox couples, e.g., Br - /Br 2, Fe (CN) 64- /Fe (CN) 63- and Ni (OH) 2 /NiOOH , have been proposed and developed, with different characteristics, challenges, maturity and prospects.
Researchers at the Pacific Northwest National Laboratory have created a new iron flow battery design offering the potential for a safe, scalable renewable energy storage system.
A new iron-based aqueous flow battery shows promise for grid energy storage applications. A commonplace chemical used in water treatment facilities has been repurposed for large-scale energy storage in a new battery design by researchers at the Department of Energy's Pacific Northwest National Laboratory.
Iron-based flow batteries designed for large-scale energy storage have been around since the 1980s, and some are now commercially available. What makes this battery different is that it stores energy in a unique liquid chemical formula that combines charged iron with a neutral-pH phosphate-based liquid electrolyte, or energy carrier.
This unique feature allows for cost-effective scaling, essential for large-scale applications. Developed using an advanced metal complex and membrane, Iron-Flow Batteries is based at the Paris Flow Tech platform – a premier hub for innovation in continuous flow chemistry.
The rapid advancement of flow batteries offers a promising pathway to addressing global energy and environmental challenges. Among them, iron-based aqueous redox flow batteries (ARFBs) are a compelling choice for future energy storage systems due to their excellent safety, cost-effectiveness and scalability.
Among the numerous all-liquid flow batteries, all-liquid iron-based flow batteries with iron complexes redox couples serving as active material are appropriate for long duration energy storage because of the low cost of the iron electrolyte and the flexible design of power and capacity.
For comparison, previous studies of similar iron-based batteries reported degradation of the charge capacity two orders of magnitude higher, over fewer charging cycles. Iron-based flow batteries designed for large-scale energy storage have been around since the 1980s, and some are now commercially available.
This work, inspired by vanadium redox flow batteries (VRFB), introduces an integrated electrochemical process for carbon capture and energy storage.
A press release by the company states that the vanadium flow battery project has the ability to store and release 700MWh of energy. This system ensures extended energy storage capabilities for various applications. It is designed with scalability in mind, and is poised to support evolving energy demands with unmatched performance.
Vanadium flow batteries provide continuous energy storage for up to 10+ hours, ideal for balancing renewable energy supply and demand. As per the company, they are highly recyclable and adaptable, and can support projects of all sizes, from utility-scale to commercial applications.
The key component of a vanadium flow battery is the stack, which consists of a series of cells that convert chemical energy into electrical energy. The cost of the stack is largely determined by its power density, which is the ratio of power output to stack volume. The higher the power density, the smaller and cheaper the stack.
It is the first 100MW large-scale electrochemical energy storage national demonstration project approved by the National Energy Administration. It adopts the all-vanadium liquid flow battery energy storage technology independently developed by the Dalian Institute of Chemical Physics.
It adopts the all-vanadium liquid flow battery energy storage technology independently developed by the Dalian Institute of Chemical Physics. The project is expected to complete the grid-connected commissioning in June this year.
The Xinhua Ushi ESS vanadium flow battery project - termed the world's largest - is located in Ushi, China.
A flow battery is a rechargeable battery with energy from two liquid chemicals separated by a membrane. These chemicals, dissolved in liquids, flow through the battery in separate loops.
Flow batteries typically include three major components: the cell stack (CS), electrolyte storage (ES) and auxiliary parts. A flow battery's cell stack (CS) consists of electrodes and a membrane. It is where electrochemical reactions occur between two electrolytes, converting chemical energy into electrical energy.
A flow battery stores energy in two soluble redox couples, which are comprised of exterior liquid electrolyte containers. During charging, one electrolyte is oxidized at the anode, while during discharging, another electrolyte is reduced at the cathode. In this way, the electrical energy is transferred to the electrolyte.
In contrast with conventional batteries, flow batteries store energy in the electrolyte solutions. Therefore, the power and energy ratings are independent, the storage capacity being determined by the quantity of electrolyte used and the power rating determined by the active area of the cell stack.
Flow battery design can be further classified into full flow, semi-flow, and membraneless. The fundamental difference between conventional and flow batteries is that energy is stored in the electrode material in conventional batteries, while in flow batteries it is stored in the electrolyte.
Scalability: One of the standout features of flow batteries is their inherent scalability. The energy storage capacity of a flow battery can be easily increased by adding larger tanks to store more electrolyte.
Flow batteries are particularly well-suited for several applications: Flow batteries excel in grid-scale energy storage, where they can store substantial amounts of energy generated from renewable sources like solar and wind. This capability helps balance supply and demand, facilitating a more stable energy grid.
Zinc–bromine batteries from different manufacturers have energy densities ranging from 34. The predominantly aqueous electrolyte is composed of zinc bromide salt dissolved in water.
Zinc-bromine flow batteries (ZBFBs) offer great potential for large-scale energy storage owing to the inherent high energy density and low cost. However, practical applications of this technology are hindered by low power density and short cycle life, mainly due to large polarization and non-uniform zinc deposition.
The energy densities for zinc-bromine and Zn-vanadium battery are 282 and 56 Wh/L catholyte, respectively (fig. S14). Since we used single-side flow batteries here, which only flow the anolyte, the high discharge of depth was achieved in all AZFB systems (fig. S17).
The history of zinc-based flow batteries is longer than that of the vanadium flow battery but has only a handful of demonstration systems. The currently available demo and application for zinc-based flow batteries are zinc-bromine flow batteries, alkaline zinc-iron flow batteries, and alkaline zinc-nickel flow batteries.
Among the above-mentioned flow batteries, the zinc-based flow batteries that leverage the plating-stripping process of the zinc redox couples in the anode are very promising for distributed energy storage because of their attractive features of high safety, high energy density, and low cost .
In particular, zinc-bromine flow batteries (ZBFBs) have attracted considerable interest due to the high theoretical energy density of up to 440 Wh kg −1 and use of low-cost and abundant active materials [10, 11].
The ZBFB delivers a peak power density of 1.363 W cm −2 at room temperature. The ZBFB stably runs over 1200 cycles (∼710 h) at 200 mA cm −2 and 60 mAh cm −2. Zinc-bromine flow batteries (ZBFBs) offer great potential for large-scale energy storage owing to the inherent high energy density and low cost.
Flow battery has recently drawn great attention due to its unique characteristics, such as safety, long life cycle, independent energy capacity and power output. It is especially suitable for large-scale storage syst.
The establishment of liquid flow battery energy storage system is mainly to meet the needs of large power grid and provide a theoretical basis for the distribution network of large-scale liquid flow battery energy storage system.
is introduced, and the topology structure of the bidirectional DC converter and the energy storage converter is analyzed. Secondly, the influence of single battery on energy storage system is analyzed, and a simulation model of flow battery energy storage system suitable for large power grid simulation is summarized.
The energy of the liquid flow energy storage system is stored in the electrolyte tank, and chemical energy is converted into electric energy in the reactor in the form of ion-exchange membrane, which has the characteristics of convenient placement and easy reuse,,, .
Redox flow batteries (RFBs) or flow batteries (FBs)—the two names are interchangeable in most cases—are an innovative technology that offers a bidirectional energy storage system by using redox active energy carriers dissolved in liquid electrolytes.
In the literature, a higher-order mathematical model of the liquid flow battery energy storage system was established, which did not consider the transient characteristics of the liquid flow battery, but only studied the static and dynamic characteristics of the battery.
This technology strategy assessment on flow batteries, released as part of the Long-Duration Storage Shot, contains the findings from the Storage Innovations (SI) 2030 strategic initiative.