Browse technical resources about solar mounting systems, tracker technology, structural design, and installation best practices.
HOME / Brilliant Technique Of Lead Acid Battery Restoration - BeTheFuture Solar Foundation & Infrastructure
The electrochemistry of static lead-acid and soluble lead-acid flow batteries is summarised and the differences between the two batteries are highlighted. A general comparison of the performance of an un.
A scaled-up soluble lead-acid flow battery has been demonstrated, operating both as a single cell and as a bipolar, two-cell stack. Using short charge times (900 s at ≤20 mA cm −2) the battery successfully runs for numerous charge/discharge cycles.
Following a large number of charge/discharge cycles, a soluble lead-acid flow battery could fail due to cell shorting caused by the growth of lead and lead dioxide deposition the negative and positive electrode, respectively.
As a flow battery, the soluble lead acid battery is also unique in that no microporous separator (typically a cation-exchange membrane such as Nafion) is required and a single reservoir is used for the electrolyte, allowing for a simpler design and a substantial reduction in cost.
Conclusions 1. The electrochemistries of the soluble lead-acid flow battery and the static lead-acid battery are distinctly different; in the soluble lead acid battery lead is highly soluble in the electrolyte of methanesulfonic acid, while lead is a solid paste in the static lead-acid battery.
Self-discharge was also observed in the case of the soluble lead-acid flow battery when it was left open-circuit for a long time period. To test the self-discharge characteristic of a soluble lead-acid flow battery, a series of charge/discharge cycles were performed.
Traditional lead-acid batteries (e.g., SLI, starting lighting ignition) batteries for automotive applications) operate with an electrolyte, typically sulphuric acid, in which lead compounds are only sparingly soluble. Consequently, an insoluble paste containing the active materials is normally applied to each of the electrodes.
Lead acid and lithium-ion batteries dominate the market. This article offers a detailed comparison, covering chemistry, construction, pros, cons, applications, and operation.
Lead-acid batteries are the oldest technology and have the shortest lifespan, making them less popular for electric cars. Ultimately, each type of battery has its own pros and cons, and it's important to consider factors like cost, lifespan, and energy efficiency when comparing electric car batteries.
Lithium-ion batteries are lighter and more compact than lead-acid batteries for the same energy storage capacity. For example, a lead-acid battery might weigh 20-30 kilograms (kg) per kWh, while a lithium-ion battery could weigh only 5-10 kg per kWh.
The primary difference lies in their chemistry and energy density. Lithium-ion batteries are more efficient, lightweight, and have a longer lifespan than lead acid batteries. Why are lithium-ion batteries better for electric vehicles?
On contrary, lead is a carcinogenic material that is harmful to the environment. Even lead-acid batteries contain other chemicals such as sulphuric acid that are poisonous. But the recycling rate for lead-acid batteries is higher than Li batteries. Also, lead-acid batteries are cheaper because of their wide availability.
Lead-acid batteries remain an essential component in the battery industry. Despite not matching the energy capacity of newer batteries, their reliability, low cost, and high current delivery make Lead-acid batteries invaluable for certain uses.
2. Lead-Acid Batteries: Working: Lead-acid batteries utilize lead dioxide as the cathode and sponge lead as the anode immersed in a sulfuric acid electrolyte. During discharge, lead and lead dioxide react with sulfuric acid to produce electricity.
The liquid-filled lead acid batteries used in automobiles and a range of other products have many great qualities, but are also known to “go bad” with little warning. Fortunately, you can easily do a basic health checkup on any.
Lead acid batteries recharge in various manners based on their function and manner of installation. For a lead acid vehicle battery, drive the vehicle around for at least 20 minutes. For a lead acid battery connected to solar panels, let the battery charge fully on a sunny day.
Fortunately, you can easily do a basic health checkup on any type of lead acid battery by hooking it up to a simple-to-use digital voltmeter. If you have an open-cell battery that lets you access the liquid inside, you can do a more rigorous checkup with a battery hydrometer. Charge the battery fully, then let it rest for 4 hours.
The liquid-filled lead acid batteries used in automobiles and a range of other products have many great qualities, but are also known to “go bad” with little warning. Fortunately, you can easily do a basic health checkup on any type of lead acid battery by hooking it up to a simple-to-use digital voltmeter.
Lead-acid batteries are a type of rechargeable battery that uses lead and lead oxide electrodes submerged in an electrolyte solution of sulfuric acid and water. They are commonly used in vehicles, backup power supplies, and other applications that require a reliable and long-lasting source of energy.
To get a more accurate reading of a lead-acid battery's health, you can use a hydrometer. This tool measures the specific gravity of the electrolyte solution within the battery, which can give you a better idea of its state of charge and overall condition. Before using a hydrometer, it's important to make sure the battery is fully charged.
Checking an open-cell lead acid battery—that is, a lead acid battery with caps that can be opened to access the liquid inside—with a battery hydrometer is most accurate when the battery is fully charged. Closed-cell lead acid batteries without the access caps cannot be tested this way.
Lead-acid batteries are suitable for applications with large capacity and low cost, while lithium batteries are suitable for occasions requiring energy density, weight and volume.
Battery storage is becoming an increasingly popular addition to solar energy systems. Two of the most common battery chemistry types are lithium-ion and lead acid. As their names imply, lithium-ion batteries are made with the metal lithium, while lead-acid batteries are made with lead. How do lithium-ion and lead acid batteries work?
Lead acid batteries, while generally safer in terms of risk of fire, can also pose risks, particularly due to their corrosive acid. However, they are generally less sensitive to environmental conditions and physical impacts compared to lithium batteries. Can lead-acid batteries and lithium batteries be charged with each other?
Electrolyte: A lithium salt solution in an organic solvent that facilitates the flow of lithium ions between the cathode and anode. Chemistry: Lead acid batteries operate on chemical reactions between lead dioxide (PbO2) as the positive plate, sponge lead (Pb) as the negative plate, and a sulfuric acid (H2SO4) electrolyte.
Lithium-ion batteries are lighter and more compact than lead-acid batteries for the same energy storage capacity. For example, a lead-acid battery might weigh 20-30 kilograms (kg) per kWh, while a lithium-ion battery could weigh only 5-10 kg per kWh.
Energy Density and Weight One of the most significant differences between lithium iron phosphate and lead acid batteries is energy density. Lithium ion batteries are much lighter and more compact, offering a higher energy density, which means they can store more energy in a smaller space.
When it comes to humidity exposure, lithium-ion batteries have better resilience than lead-acid. Lithium-ion batteries have a robust casing that is completely sealed, therefore, moisture does not get to the internal components of the battery.
Slower charging occurs when a lead acid battery takes longer to reach a full charge. Aging batteries exhibit increased internal resistance, which impedes the flow of current during charging.
Experiments on a 12 V 50 Ah Valve Regulated Lead Acid (VRLA) battery indicated the possibility of 100 % charge in about 6 h, however, with high gas evolution. As a result, the feasibility of multi-step constant current charging with rest time was established as a method for fast charging in lead-acid batteries.
The following mainly analyzes the lead-acid battery short circuit caused by excessive charging current, charging voltage of a single battery exceeds 2.4V, internal short-circuit or partial discharge, excessive temperature rise and valve control failure, and summarizes the treatment methods of lead acid battery short circuit as follows:
Lead acid is sluggish and cannot be charged as quickly as other battery systems. (See BU-202: New Lead Acid Systems) With the CCCV method, lead acid batteries are charged in three stages, which are constant-current charge, topping charge and float charge.
Even in storage, lead-acid batteries naturally lose charge over time, and failure to periodically recharge them can result in irreversible damage. 8. Proper Disposal and Recycling of Lead-Acid Batteries Lead-acid batteries contain hazardous materials, including lead and sulfuric acid, making proper disposal crucial.
Temperature Control: Ideally, lead-acid batteries should be charged at temperatures below 80°F (27°C). Charging at high temperatures can lead to thermal runaway, where the battery overheats and becomes damaged. If your battery becomes hot to the touch during charging, stop the process immediately and allow it to cool. 4. Avoiding Overcharging
The most important first step in charging a lead-acid battery is selecting the correct charger. Lead-acid batteries come in different types, including flooded (wet), absorbed glass mat (AGM), and gel batteries. Each type has specific charging requirements regarding voltage and current levels.
Acid stratification happens when the heavier acid in the battery's electrolyte separates from the water and assembles at the bottom of the battery's cell, creating an area of very high specific gra.
Construction, Working, Connection Diagram, Charging & Chemical Reaction Figure 1: Lead Acid Battery. The battery cells in which the chemical action taking place is reversible are known as the lead acid battery cells. So it is possible to recharge a lead acid battery cell if it is in the discharged state.
Following are some of the important applications of lead – acid batteries : As standby units in the distribution network. In the Uninterrupted Power Supplies (UPS). In the telephone system. In the railway signaling. In the battery operated vehicles. In the automobiles for starting and lighting.
During the charging cycle, lead sulfate converts back into lead dioxide and spongy lead, effectively restoring the battery's energy storage capacity. Lead-acid batteries naturally lose charge over time, even when not in use.
The construction of a lead acid battery cell is as shown in Fig. 1. It consists of the following parts : Anode or positive terminal (or plate). Cathode or negative terminal (or plate). Electrolyte. Separators. Anode or positive terminal (or plate): The positive plates are also called as anode. The material used for it is lead peroxide (PbO 2).
In the charging process we have to pass a charging current through the cell in the opposite direction to that of the discharging current. The electrical energy is stored in the form of chemical form, when the charging current is passed. lead acid battery cells are capable of producing a large amount of energy.
Lead-acid batteries, widely used across industries for energy storage, face several common issues that can undermine their efficiency and shorten their lifespan. Among the most critical problems are corrosion, shedding of active materials, and internal shorts.
To clean sulfuric acid, use a solution of one pound of baking soda per gallon of water. Apply with a cloth or sponge, and avoid splashing or spreading the acid.
To clean up battery acid spills, first put on a pair of rubber gloves as well as a safety mask or goggles. Place the battery in 2 plastic bags, seal the bags tightly, and inspect the battery label to see what type it is. For an alkaline battery, clean up the spill using a mild acid like vinegar or lemon juice.
Clean up alkaline spills with mild household acid. For alkaline batteries, dip a cotton swab in vinegar or lemon juice and apply a few drops to the affected area. Use a cotton swab dipped in 90 to 99% isopropyl alcohol to remove residue. Wipe the area with a microfiber cloth, then let the device dry for several hours.
Do not use baking powder to clean battery acid. This can form a conductive paste that can create an electric short and ruin your device. If you notice that the batteries in your device are leaking, it should be cleaned immediately. Any battery-operated electronic devices should be checked regularly to ensure that there's no battery leakage.
Because vinegar and lemon juice are mild acids, they help neutralize the base and cut through a battery spill fairly easily. On most gadgets with simple circuitry, the negative battery connector is usually held down by a screw or clip. You should be able to remove this easily and clean it separately. Place a towel underneath to catch any overspill.
Similarly, when alkaline batteries leak, they can corrode the battery compartment and contacts and prevent your device from working. Fortunately, you can clean up both kinds of battery corrosion easily with a few household supplies and basic tools.
While alkaline batteries emit a fluid that eventually turns into a white powdery crust, lithium-ion batteries abruptly stop working or they heat up, catch fire, or, in rare cases, explode. To clean battery acid, you first need to neutralize it with a mild acid. Ordinary white vinegar —the type found in the kitchen—is the best product to begin with.
In the CML impact categories, most of the impact (>85 %) was discovered to stem from the production of lead metal, rather than the production of the sheet that results from the lead. An exception to this was ozone depletion potential, which also sees a significant share stemming from sheet production. This can be seen in. Following on from the Lead Sheet LCA study, a socio-economic assessment was conducted using the LCA data (RPA 2014 internal report). Life cycle.
Lead-based batteries LCA Lead production (from ores or recycled scrap) is the dominant contributor to environmental impacts associated with the production of lead-based batteries. The high recycling rates associated with lead-acid batteries dramatically reduce any environmental impacts.
Table 2. Life cycle impact assessment results for 1 kWh lead acid batteries used in e-bikes with an average service life. Energy and resource use. Overall, primary energy use (PEU) totals 4635 MJ for 1 kWh capacity of LABs throughout the life cycle, 84% of which is contributed by electricity consumption in the use stage.
For all battery technologies, the contribution of lead production to the impact categories under consideration was in the range of 40 to 80 % of total cradle-to-gate impact, making it the most dominant contributor in the production phase (system A) of the life cycle of lead-based batteries.
Mining and smelting have the greatest environmental impacts for lead production. The main contributors in mining and concentration are the fuel combustion and power production. Study represented 80 % of production technology but only 32 % of ILA members. Lead-based batteries LCA
The high recycling rates associated with lead-acid batteries dramatically reduce any environmental impacts. In terms of global warming potential, the environmental advantage of improved and advanced technology lead-based batteries during the use phase far outweighs the impacts of their production.
The lead battery LCA assesses not only the production and end of life but also the use phase of these products in vehicles. The study demonstrates that the technological capabilities of innovative advanced lead batteries used in start-stop vehicles significantly offset the environmental impact of their production.
Sealed lead acid batteries may be charged by using any of the following charging techniques: 1. Constant Voltage 2. Constant Current 3. Taper Current 4. Two Step Constant Voltage To obtain maximum battery ser. During constant voltage or taper charging, the battery's current acceptance decreases as voltage and state of charge increase. The battery is fully charged once the current stabilize. Selecting the appropriate charging method for your sealed lead acid battery depends on the intended u. Constant voltage charging is the best method to charge sealed lead acid batteries. Depending on the application, batteries may be charged either on a continuous or no. Constant current charging is suited for applications where discharged ampere-hours of the preceding discharge cycle are known. Charge time and charge quantity can easily be cal.
The lead-acid battery mainly uses two types of charging methods namely the constant voltage charging and constant current charging. It is the most common method of charging the lead acid battery. It reduces the charging time and increases the capacity up to 20%. But this method reduces the efficiency by approximately 10%.
Just multiply the voltages by 2 for 24V or 4 for 48V batteries. The only way to get an accurate reading of a lead acid battery's state of charge from voltage is to measure its open circuit voltage. This means the battery must be disconnected from all loads and chargers and allowed to rest for several hours until its voltage stabilizes.
The optimal charging voltage for 48V flooded lead acid batteries is typically around 58V to 62V at the start of charging. Sealed batteries may need slightly higher voltages. Refer to the battery specifications. How Can I Revive a Dead Lead Acid Battery?
Customers often ask us about the ideal charging current for recharging our AGM sealed lead acid batteries. We have the answer: 25% of the battery capacity. The battery capacity is indicated by Ah (Ampere Hour). For example: In a 12V 45Ah Sealed Lead Acid Battery, the capacity is 45 Ah.
For example: In a 12V 45Ah Sealed Lead Acid Battery, the capacity is 45 Ah. So, the charging current should be no more than 11.25 Amps (to prevent thermal runaway and battery expiration). Importantly, if you have other equipment connected to the battery during chargning, it also needs to be powered, so you need to add that to your calculations.
In this method the charging current is high in the beginning when a battery is in discharged condition, and it gradually drops off as the battery picks up charge resulting in increased back emf. Charging at constant voltage may be carried out only when the batteries have the same voltage, for example, 6 or 12 or 24 V.
Removing a laptop's battery causes power disruption, risking data loss during power outages. Some brands, like HP and Dell, can operate without a battery. However, this may alter BIOS settings.
1) Remove laptop battery physically This option works fine for me. I just need to plug in charger all the time so it doesn't shut down accidentally without turning off important apps. 2) Disable battery in Device Manager (Microsoft ACPI-Complaint Control Method Battery) (Not to be confused with "Uninstall Device driver for this device")
If you disable the battery in device manager it would just stop Windows from reading battery's information, it doesn't stop it from being used by the laptop. I wonder who do I trust? Are you sure that disabling battery would also stop the battery from being charged when laptop is working on charger?
Many users say that: If you disable the battery in device manager it would just stop Windows from reading battery's information, it doesn't stop it from being used by the laptop. I wonder who do I trust?
I did some research online and learned that when you remove the CMOS battery it will reset certain things. But, exactly what this will reset and how to change it back (once you put the CMOS battery back in) to the "before removal state" can vary by computer.
This depends on the laptop; you're unlikely to break it, but some laptops will refuse to power on without a battery in place (that is, they always draw power from the battery). You must log in to answer this question.
There are various capacitors present in or near this circuit. I've read anywhere from 30 secs to 25 minutes (even one site said a few days) to wait after removing the CMOS battery. I've also read that some laptops have a "hidden IC which stores the password" or that the password may be stored on a sector of the hard drive.
For the purposes of this document, the following terms and definitions apply; Power Generating Modules are categorised in EREC G99 as Power Park Modules (PPM) or Synchronous Power Generating Modules (SPGM). Both contain one or more. When you are ready to submit a formal application for connection, we will require information from you to enable us to make a reasonable assessment of the works required to facilitate the. Discussing your plans with us at an early stage can help to provide a better insight to any potential network reinforcement and complexity issues that. If you are not ready to enter into a formal agreement for connection works, or you do not yet have full details of the specific conditions required, you.
Learn how raw materials like lead, sulfuric acid, and water come together to form these essential energy storage devices. From grid casting to battery formation, we explain each step in detail.
This document provides an overview of the lead acid battery manufacturing process. It discusses the key steps which include alloy production, grid casting, paste mixing and pasting, plate curing, and assembly. The alloy production process involves preparing mother alloy and KL-alloy from reclaimed lead using furnaces.
The lead battery is manufactured by using lead alloy ingots and lead oxide It comprises two chemically dissimilar leads based plates immersed in sulphuric acid solution. The positive plate is made up of lead dioxide PbO2 and the negative plate with pure lead.
A typical lead–acid battery contains a mixture with varying concentrations of water and acid. Sulfuric acid has a higher density than water, which causes the acid formed at the plates during charging to flow downward and collect at the bottom of the battery.
During the charging process, the cycle is reversed, that is, lead sulphate and water are converted to lead, lead oxide and electrolyte of sulphuric acid by an external charging source. This process is reversible, which means lead acid battery can be discharged or recharged many times.
The positive plate is made up of lead dioxide PbO2 and the negative plate with pure lead. The nominal electric potential between these two plates is 2 volts when these plates are immersed in dilute sulfuric acid. This potential is universal for all lead acid batteries.
In applications, a nominal 12V lead-acid battery is frequently created by connecting six single-cell lead-acid batteries in series. Additionally, it can be incorporated into 24V, 36V, and 48V batteries. Further, the lead acid manufacturing process has been discussed in detail. Lead Acid Battery Manufacturing Equipment Process 1.
Solar lights have rechargeable batteries that last about four years without replacements, while the lights and LED fixtures can last approximately ten years.
On the other hand, NiCad batteries may reduce the lifespan of solar lights to just 1 year because of memory problems. The longevity of solar lights can range from 6 months to 2 years based on the type of battery used. Understanding the impact of battery technology on solar lights is important for ensuring their durability.
Solar batteries store energy generated from solar panels. These components play a key role in your solar system, especially when it comes to energy availability during power outages or low sunlight conditions. Lead-acid batteries are the most common type used in solar systems. They can last around 3 to 5 years, depending on usage and maintenance.
To improve solar light longevity, consider placing the lights in areas with direct sunlight for at least 6-8 hours each day. Keep the solar panels clean and free from any debris to ensure maximum sunlight absorption. Additionally, switching off the lights when not in use can help extend battery life.
Keep the solar panels clean and free from any debris to ensure maximum sunlight absorption. Additionally, switching off the lights when not in use can help extend battery life. When it comes to making the most of your solar lights, keeping an eye on the battery life is crucial. Regular monitoring guarantees they stay lit up when needed.
If you're considering whether or not to get a solar battery, one of the deciding factors will be how long they last. After all, with solar panels typically lasting 25-30 years, you'll want to know how many battery systems you'll have to buy to match your panels' lifespan.
Lithium-ion batteries stand out for their longevity and performance. Typically, they last between 10 to 15 years. Their design allows for a higher depth of discharge (DoD), meaning you can use more of the stored energy without harming battery life.
The full battery designation identifies not only the size, shape and terminal layout of the battery but also the chemistry (and therefore the voltage per cell) and the number of cells in the battery. For example, a CR123 battery is always LiMnO 2 ('Lithium') chemistry, in addition to its unique size. This is a list of the sizes, shapes, and general characteristics of some common primary and secondary in household, automotive and light industrial use. The complete no. Coin-shaped cells are thin compared to their diameter. is usually stamped on the metal casing. The IEC prefix "CR" denotes lithium manganese dioxide chemistry. Since LiMnO2 cells pro.
Batteries can be classified according to their chemistry or specific electrochemical composition, which heavily dictates the reactions that will occur within the cells to convert chemical to electrical energy. Battery chemistry tells the electrode and electrolyte materials to be used for the battery construction.
Although BCI is the most common battery group classification system in the United States, others do exist. EN and DIN are other battery group classification systems that you will sometimes see in owner's manuals or when shopping for batteries.
In this study, two types of classification settings are considered. The first setting considers y i = {0 1}, which is a binary classification task grouping batteries into {s h o r t, l o n g} lifetime.
The complete nomenclature for a battery specifies size, chemistry, terminal arrangement, and special characteristics. The same physically interchangeable cell size or battery size may have widely different characteristics; physical interchangeability is not the sole factor in substituting a battery. [ 1 ]
Considering the above, it appears timely to propose a simple and uniform classification system encompassing all battery types. Conceptually, every battery is simply made of three layers: positive electrode layer, electrolyte layer, negative electrode layer.
Primary batteries come in three major chemistries: (1) zinc–carbon and (2) alkaline zinc–manganese, and (3) lithium (or lithium-metal) battery. Zinc–carbon batteries is among the earliest commercially available primary cells. It is composed of a solid, high-purity zinc anode (99.99%).
These include:Ensuring batteries are separated from habitable rooms and escape routes by appropriate fire compartmentation. Providing fire detection for the battery location, linked to a fire alarm system to alert inhabitants of a fire.
To minimise the risk of batteries becoming a fire hazard, a new British Standard covering fire safety for home battery storage installations came into force on 31 March 2024. The standard is – PAS 63100:2024: Electrical installations. Protection against fire of battery energy storage systems (BESS) for use in dwellings.
With this in mind, it's reasonable to question the fire risks posed by home battery storage systems. As we explain below, home battery fire risk is not something you need to lose sleep over. Read on to find out more. Why do batteries catch fire? Li-on batteries are essential in modern society.
It should be noted that fires from domestic home energy storage batteries are extremely rare. Most Home energy batteries use Lithium Iron Phosphate technology (LiFePO4). Whilst this technology makes for a heavier battery, it is known to be very safe and does not catch fire under any normal circumstances.
In September 2020, the UK government published a review of safety risks related to domestic battery energy storage systems. In the document, it acknowledges that 'few incidents with domestic battery energy storage systems are known in the public domain'. At the same time, the report recognises that relevant safety measures need to be implemented.
Even though few incidents with domestic battery energy storage systems (BESSs) are known in the public domain, the use of large batteries in the domestic environment represents a safety hazard.
Battery energy storage systems (BESS), also known as Electrical Energy (Battery) Storage systems or solar batteries, are becoming increasingly popular for residential units with PV solar installations, and (although much less frequently) small wind-turbines¹.
When the electrolyte in a lithium-ion battery freezes, it can cause the formation of lithium metal on the surface of the electrodes inside the battery. This can create a physical barrier that prevents the flow of ions between the. To maximize the efficiency of a lithium-ion battery at low temperatures, there are several strategies that can be used: 1.Keep the battery warm: One of the most effective ways to maintain. The runtime of a lithium-ion battery depends on several factors, including the capacity of the battery, the power requirements of the device.
Low-temperature batteries are designed to maintain performance in cold environments. In contrast, standard batteries often experience reduced capacity and efficiency in low temperatures.
Battery certification plays a crucial role in ensuring the safety and performance of battery products across various industries. In this guide, we'll break down the essential certifications you need to know, including the types of certifications, the costs involved, expected timeframes, and the standards that govern them.
Low-temperature batteries may sacrifice some capacity or energy density to maintain performance in cold environments. In contrast, standard batteries typically offer higher capacity and energy density under normal operating conditions. Standard batteries may perform better in moderate temperatures but struggle in colder climates.
The lowest temperature at which most batteries can operate without damage is typically around -20 °C to -40 °C (- 4°F to 40°F). However, this can vary depending on the type of battery and its chemistry. What is the low temperature for a LiPo battery? LiPo batteries perform best at temperatures above 0°C (32°F).
LiFePO4 batteries can generally operate safely down to around -20°C. Beyond this temperature, their performance may decline, potentially damaging them. The low temperature li-ion battery solves energy storage in extreme conditions. This article covers its definition, benefits, limitations, and key uses.
In Europe, lithium-ion batteries must meet CE Marking requirements for safety, health, and environmental standards. Additional certifications like IEC 62133 or UN38.3 may be needed for transport and use. What to consider when choosing a certification body?